PGF115 Stage 2

Product features: high precision, high torque, high rigidity, high efficiency, high stability, low noise, low backlash.

Product introduction: It can be used with stepper motors or servo motors to reduce speed, increase torque, increase motor rotor inertia, improve rigidity, shorten start and stop positioning time, miniaturize motor power, and improve inertial load stability and reduce vibration. Single-stage can reach within 3 arc minutes, and double-stage can reach within 5 arc minutes.

Parameter Table

Specifications Level Reduction ratio PGF115
Rated output torque Nm 2 20 270
25 330
35 330
40 330
50 330
70 300
100 140
Maximum output torque Nm 1,2 4~100 3 times rated output torque
Rated input speed rpm 1,2 4~100 4000
Maximum input speed rpm 1,2 4~100 8000
Ultra-precision backlash P0 arcmin 1 4~10 ≤1
2 20~100 ≤3
Precision backlash P1 arcmin 1 4~100 ≤3
2 20~100 ≤5
Standard backlash P2 arcmin 1 4~10 ≤5
2 20~100 ≤7
Moment of inertia Nm/arcmin 1,2 4~100 82
Maximum bending moment M2KB² Nm 1,2 4~100 430
Allowable axial force F2B² N 1,2 4~100 4800
Service life hr 1,2 4~100 30000
Efficiency 1 4~10 ≥97%
2 20~100 ≥94%
weight kg 1 4~100 5.6
2 20~100 7.3
0perating temperature 1,2 4~100 .-10℃~+90℃
Lubrication 1,2 4~100 Synthetic lubricating grease
Protection level 1,2 4~100 IP65
Installation method 1,2 4~100 Any direction
Noise value(n1=3000rpm) dB 1,2 4~100 ≤63
Specifications Level Reduction ratio PGF42 PGF60 PGF90 PGF115 PGF142 PGF180 PGF220
Moment of inertia kg · cm² 1 4 0.03 0.14 0.51 2.87 7.54 25.03 58.31
5 0.03 0.13 0.47 2.71 7.42 23.29 53.27
7 0.03 0.13 0.45 2.62 7.14 22.48 50.97
8 0.03 0.13 0.45 2.57 7.14 22.48 50.97
10 0.03 0.13 0.44 0.47 7.03 22.51 50.56
2 20 0.03 0.03 0.13 0.47 2.71 7.42 23.29
25 0.03 0.03 0.13 0.47 2.71 7.42 23.29
35 0.03 0.03 0.13 0.47 2.71 7.42 23.29
40 0.03 0.03 0.13 0.44 2.57 7.03 22.51
50 0.03 0.03 0.13 0.44 2.57 7.03 22.51
70 0.03 0.03 0.13 0.44 2.57 7.03 22.51
100 0.03 0.03 0.13 0.44 2.57 7.03 22.51
Note: 1. Reduction ratio (i=Nin/Nut) 2. When the output speed is 100rpm, it acts on the center position of the output shaft* Continuous operation reduces the service life by half.

Ordering Instructions / Customer Fill Out

 

Contact us